Energy Saving Features Of Office Buildings
Listed below are a few of the features that you as a tenant will
receive by leasing one of our office buildings.
High-performance reflective dual glazing –
- Few buildings
in the United States have glazing with the thermal qualities
as this one. Both the shading coefficient and U factor are extremely
low, reducing energy consumption.
-
High-efficiency lighting with motion detectors –
- This
building was built with a lighting density of 0.9 watts per square
foot even though the code at the time allowed lighting to 1.5
watts per square foot. On July 1, 2000 the code reduced allowable
lighting to 1.2 watts per square foot so Plaza del Rio is still
more efficient than the current code by 25%. On June 1, 2001 the
code finally began requiring motion detectors.
-
Novar building management system –
- A system with the capabilities
of your Novar controls is still not required by code. It allows
remote monitoring of each zone and of the HVAC equipment for
fine-tuning adjustments and start/stop times to minimize energy
consumption. It also allows logging of data such as room temperatures,
runtime hours, etc.
-
After-hours billing –
- The Novar system in combination with
the E-Mon meters allows very exact after-hours billings to tenants.
A system with this sophistication is very rare and as far as
we know Park View Plaza, Plaza del Rio, Village Courtyard West,
and Village Courtyard East are the only buildings in the Fresno
area with this ability. Tenant hours of operation correlate directly
with energy consumption. The Novar system allows the tenant to
determine how many zones to turn on with the override (as small
as 750 square feet of space) so that energy use is minimized.
-
High-Efficiency Rooftop Cooling Units –
- The cooling plant
for each floor is a high EER cooling unit. The units include
oversized condenser sections to increase the EER by approximately
ten percent.
-
Economizer Controls –
- Motorized return and outside air
dampers modulate automatically to allow the use of outside air
for free cooling when the temperature outside is cool enough.
This feature reduces cooling energy consumption and extends compressor
life.
-
Variable speed drives –
- The supply and return blower motors
in each rooftop cooling unit are premium grade (highest efficiency)
and have variable speed drives which dramatically reduce fan
energy during the year and makes low after-hours’ costs
possible. Our technicians use the Novar system to monitor and
adjust the maximum air volume allowed to each zone resulting
in a significant reduction in total air volume in the building
thus reducing fan energy notably.
-
Fan-Powered VAV boxes –
- The installation of this type of
variable air volume box (VAV) serving the perimeter zones allows
heat from the lights that pass through slots in the light fixtures
to be used to heat the perimeter saving considerable energy.
In fact, most of the heating hours of the year the lights are the
only source of heat.
-
Demand Ventilation –
- Each rooftop unit is equipped with CO2
sensors that measure CO2 levels in the return air. The outside
air dampers then modulate to reduce unnecessary outside air during
periods when occupancy is low.
List of Awards (Energy Star®)
- Plaza del Rio – Awarded Energy Star in 2003
- Village Courtyard West – Awarded Energy Star in 2004

|